Utilize este identificador para referenciar este registo: http://hdl.handle.net/10400.2/3645
Título: Electrolytic conductivity of four imidazolium-based ionic liquids
Autor: Calado, Marta
Diogo, João C. F.
Mata, José L. Correia da
Caetano, Fernando J. P.
Visak, Zoran P.
Fareleira, João M. N. A.
Palavras-chave: Electrolytic conductivity
Imidazolium-based ionic liquids
Data: Ago-2013
Editora: Int J Thermophys
Resumo: In this article, electrolytic (ionic) conductivity measurements of four ionic liquids (ILs), namely, 1-ethyl-3-methylimidazolium bis[(trifluoromethyl)sulfonyl] imide ([C2mim][NTf2]), 1-ethyl-3-methylimidazolium trifluoromethanesulfonate ([C2mim][OTf]), 1-hexyl-3-methylimidazolium bis[(trifluoromethyl)sulfonyl]imide ([C6mim][NTf2]), and 1-ethyl-3-methylimidazolium ethyl sulfate ([C2mim][EtSO4]) (ECOENG212 ), were performed in a temperature range of (288.15 to 333.15) K. [C6mim][NTf2] was chosen to be a reference ionic liquid for several properties, including the electrolytic conductivity by the IUPAC Project 2002-005-1-100. For that reason, the measurements performed with that ionic liquid primarily serve the purpose to validate the instrumentation and the experimental procedure used in this work. The measurements were carried out using a complex impedance method, applying a novel electronic device designed and constructed for this purpose. The complete setup includes a Schott Instruments LF 913 T, used as a four-electrode conductivity cell, and a lock-in amplifier. The cell was calibrated using standard reference KCl aqueous solutions. The measurements of the impedance of the conductivity cell were carried out along a range of frequencies from (0.2 to 30) kHz, and the results were extrapolated to infinite frequency, in order to determine the electrolytic conductivity of the liquid samples. The results obtained for the ionic liquid [C6mim][NTf2] were compared to reference data, and it was estimated that the overall uncertainty of the present results is better than 2%. All the data obtained were compared with available literature data, and were analyzed and discussed in respect to the effect of temperature, cation alkyl chain length, and anion.
Peer review: yes
URI: http://hdl.handle.net/10400.2/3645
DOI: 10.1007/s10765-013-1491-2
ISSN: 0195-928X (Print)
1572-9567 (Online)
Versão do Editor: http://link.springer.com/article/10.1007%2Fs10765-013-1491-2
Aparece nas colecções:Ciências e Tecnologia - Artigos em revistas internacionais / Papers in international journals



FacebookTwitterDeliciousLinkedInDiggGoogle BookmarksMySpace
Formato BibTex MendeleyEndnote Degois 

Todos os registos no repositório estão protegidos por leis de copyright, com todos os direitos reservados.